XLPE

ARMOURED & UNARMOURED CABLES

Application:

These cables are designed for general use, including underground burial, where they are not likely to suffer mechanical damage. They have a molecular structure that allows them to bond with a strong resistance to deformation even at high temperature.

 

An important advantage of the insulation for medium and high voltage cables is its low dielectric loss. The dielectric loss factor is approximately one decimal power less than that of paper insulated cables and approximately two decimal powers less than that of PVC insulated cables.

Unarmoured cable

6981G

Table 18

Single core, stranded circular copper conductor, XLPE insulated, PVC sheath. Voltage rating 600/1000V. BS5467. Unarmoured cable.

Identification - Product identification and legend are printed on the outer sheath.

Nominal area of conductor

Conductor formation

Conductor weight

Insulation

Bedding

Sheathi g

Cable weight

Current rating

Voltage Drop per amp per meter mV

mm sq

No. of wires

wire size mm

kg/km

average thickness mm

diameter mm

average Thickness mm

diameter mm

kg/km

sing:ne ja:iih nase amps

50

19

1.85

413

1

13.6

1.4

142

540

225

1

70

19

2.2

596

1.1

15.6

1.4

16.2

750

289

0.73

95

19

2.6

826

1.1

17.5

1.5

18.3

1010

352

0.56

120

36

2.1

1045

1.2

19.2

1.5

202

1250

410

0.47

150

36

2.33

1283

1.4

21.3

1.6

22.4

1530

473

0.41

185

36

2.6

1611

1.6

23.4

1.6

24.7

1900

542

0.36

240

60

2.33

2116

1.7

26.3

1.7

27.7

2470

641

0.31

300

59

2.6

2656

1.8

29

1.8

30.6

3080

741

0.29

400

60

2.88

3383

2

32.7

1.9

34.2

3890

865

0.27







armoured cable

6943G

Table 19

Three core, stranded cooper conductor, XLPE insulated, Brown, Grey and Blue laid up and taped bedding, steel wire armoured, PVC sheathed. Voltage rating 600/1000V, BS5467. For power supply indoor, outdoor and underground.

Identification - Product identification and legend are printed on outer sheath.

Nominal area of conductor

Conductor formation

Conductor weight

Insulation

Dia over laid up cores

Armouring

Sheathing

Cable weight

Current ating

mm sq

No. of wires

wire

size mm

kg/km

average thickness

mm

average thickness

mm

wire

size mm

diameter

mm

kg/km

in air at 30°C amps

in duct amps

in ground at 15°C amps

6

7

1.04

52.3

0.7

0.8

0.9

16.6

689

51

56

69

10

7

0.35

88.05

0.7

0.8

1.25

19.5

9.8

70

75

92

16

7

1.75

139.5

0.7

16.1

1.25

21.8

1070

99

96

119

25

7

2.2

220

0.9

20.3

1.6

26.9

1550

131

124

152

35

7

2.6

305

0.9

22.8

1.6

29.6

1940

162

149

182

50

19

1.85

413

1

21.6

1.6

28.4

2360

197

177

217

70

19

2.2

596

1.1

25

1.6

32

3120

251

208

266

95

19

2.6

826

1.1

28.5

2

36.7

4310

304

263

319

120

36

210

1045

1.2

31.6

2

40

5160

353

300

333

150

36

2.33

1283

1.4

35.5

2.5

45.1

6610

406

338

406

185

36

2.6

1611

1.6

39.5

2.5

49.3

7920

465

382

458

240

60

2.33

2116

1.7

44.3

2.5

54.5

9930

546

442

529

300

59

2.6

2656

1.8

49.1

2.5

59.5

11970

628

486

592

400

60

2.88

2283

2

55

2.5

65.8

14470

740

570

667







6944G

Table 20

Four core, shaped stranded copper conductor, XLPE insulated. Brown, Grey, Blue and Black laid up and taped bed-ded, steel wire armoured, PVC sheathed. voltage rating 600/1000V, BS5467. For power supply indoor, outdoor and underground,

Identification - Product identification and legend are printed on outer sheath.

Nominal area of conductor

Conductor formation

Conductor weight

Insulation

Bedding

Armouring

Sheathing

Cable weight

Current rating

mm sq

No. of wires

wire size mm

kg/km

average thickness mm

thickness mm

wire size mm

diameter mm

kg/km

in air at 30°C amps

in duct amps

in ground at15°C amps

6

7

1,04

52.3

0.7

0.8

0.9

18.7

795

-

56

69

10

7

0.35

88.05

0.7

0.8

1.25

21.1

10.64

-

75

92

16

7

1.75

139.5

0.7

1

1.25

22.9

1300

99

96

119

25

7

2.2

220

0.9

1

1.6

25.7

1880

131

124

152

35

7

2.6

305

0.9

1

1.6

2`8.4

2350

162

149

182

50

19

1.85

413

1

1

1.6

31.6

2950

197

177

217

70

19

2.2

596

1.1

1.2

2

36.9

4230

251

208

266

95

19

2.6

826

1.1

1.2

2

40.9

5390

304

263

319

120

36

2.1

1045

1.2

1.2

2.5

45.9

6980

353

300

333

150

36

2.33

1283

1.4

1.2

2.5

50.2

8300

406

338

406

185

36

2.6

1611

1.6

1.2

2.5

55.4

10070

465

382

458

240

60

2.33

2116

1.7

1.2

2.5

61.4

12680

546

442

529

300

59

2.6

2656

1.8

1.2

2.5

67.2

15380

628

486

592

400

60

2.88

3383

2

1.2

3.15

76.1

19950

740

570

667







694(3½)G

Table 21

Three core with reduced, neutral shaped stranded copper conductor, XLPE insulated. Brown, Grey, Blue and Black laid up and taped bedded, steel wire armoured, PVC sheathed. voltage rating 600/1000V. BS5467. for power supply indoor, outdoor and underground.

Identification - Product identification and legend are printed on outer sheath.

Nominal area of conductor

Conductor formation

Conductor weight

Insulation thickness

Dia over laid up cores

Armour- ing

Sheath- ing

Cable weight

Current rating

(Phase) mm sq

(neutral) mm sq

No. of
wires

Wire
size mm

No. of wires

Wires
size mm

Phase
kg/km

Neutral kg/km

Phase mm

Neutral mm

mm

Wire size mm

Diameter mm

mm

in air amps

in duct amps

in ground amps

25

16

7

2.2

7

1.75

220

139.5

0.9

0.7

-

1.6

25.7

1880

131

124

152

35

16

7

2.6

7

1.75

305

139.5

0.9

0.7

-

1.6

27.6

2350

162

149

182

50

25

19

1.85

7

2.2

413

220

1

0.9

24.3

1.6

30.8

2950

197

177

217

70

35

19

2.2

7

2.6

596

305

1.1

0.9

28.6

2

35.8

4230

251

208

266

95

50

19

2.6

19

1.85

826

413

1.1

1

32.2

2

40.2

5390

304

263

319

120

70

36

2.1

19

2.2

1045

596

1.2

1.1

36.2

2

44.5

6980

353

300

222

150

70

36

2.33

19

2.2

1283

596

1.4

1.1

40.1

2.5

48.5

8300

406

338

406

185

95

36

2.6

19

2.6

1611

826

1.6

1.1

44.7

2.5

54.1

10070

465

382

458

240

120

60

2.33

36

2.1

2116

1045

1.7

1.2

50.6

2.5

59.4

12680

546

442

529

300

150

59

2.6

36

2.33

2656

1283

1.8

1.4

55.7

2.5

65.1

15380

628

486

592

400

185

60

2.88

36

2.6

3383

1611

2

1.6

62.7

2.5

72.2

19950

740

570

667

CONTACT CENTER

YATSA CORPORATION

4250 Broadway I Suite 3W

NEW YORK, NY. US 10033

 

(347) 351-9094

yatsacorporation@gmail.com