for inAdustrial wiring and mains distribution.

Power & Control Cables

PVC Power Cable:

 

Application:

Designed for use in mains supply electricity. These cables are provided with mechanical protection are therefore suitable for external use and direct burial.

Steel Wire Armoured cables are predominantly used for industrial wiring and mains distribution. They are designed to be used in industrial areas, in and around buildings and other similar environments. These cables are designed to be installed in air, clipped to surface, on cable tray/ladder work, embedded in concrete and buried direct or in ducting underground.

6942X

Table 9

Three core and earth insulated, Brown, Grey and Blue, with bare Circuit Protective Conductor (CPC), White sheathed, overall flat. For surface installation. Voltage rating 300/500V. Stranded copper conductor PVC insulated and sheathed.

Identification - Product identification and legend are printed on outer sheath.

Nominal area of cond`uctor

Conductor

formation

Conductor

weight

Insulation

Dia. over

laid up

cores

Armouring

Sheath-

ing

Cable

weight

Current rating

mm sq

No.

of

wires

wire

size

mm

gm

avg.

thkns.

mm

diam.

mm

mm

wire

size

mm

No.

of

wires

diam.

mm

diam.

(max.)

mm

kg/km

in air

amps

in duct

amps

in

ground

amps

1.5

7

0.53

13.65

0.7

3.06

6.12

0.90

27

9.52

12.3

290

22

26

32

2.5

7

0.67

21.8

0.8

3.69

7.38

0.90

31

10.78

13.6

356

31

34

41

4

7

0.85

34.95

0.8

4.22

8.44

0.90

36

11.84

15.1

438

41

45

55

6

7

1.04

52.3

0.8

4.79

9.58

0.90

39

12.98

16.5

524

53

57

69

10

7

1.35

88.05

1

6.15

12.3

1.25

35

16.4

20.1

840

72

76

92

16

7

1.75

139.5

1

6.95

-

-

-

-

21.9

990

97

98

119

25

7

2.2

220

1.2

-

13.3

1.6

29

18.1

22.6

1266

128

129

158

35

7

2.6

305

1.2

-

14.88

1.6

32

19.68

29

1527

157

154

190

50

19

1.85

413

1.4

-

17.36

1.6

36

22.16

27.4

1958

190

183

225

70

19

2.2

596

1.4

-

19.56

1.6

40

24.36

30

2439

241

225

277

95

19

2.6

826

1.6

-

23.04

2

37

28.64

34.7

3406

291

271

332

Sizes 1.5mm2 to 10.0mm2 are extruded bedded, and sizes 1.5mm2 to 16mm2 are circular standed. Conductors of 25.0mm sq. and above are shaped stranded conductors.







6943X

Table 10

Three stranded copper conductor. PVC insulated cores. Brown, Grey and Blue, laid up and tape bedded, steel wire armoured, PVC Sheathed. Voltage rating 600/1000V. BS6346 - J593. For power supply indoor, outdoor or underground.

Identification - Product identification and legend are printed on outer sheath.

Size

Condr. Form.

Condr. Weight

Insulation thickness

Dia over laid up cores

Armouring

Sheathing

Cable weight

Current rating

mm sq

No. of wires

wire size mm

(nom) g/m

(ave.) mm

(min.) mm

No. of wire mm

Wire size mm

Dia. (nom.) mm

Dia. (max.) mm

kg/km

Laid direct in grounds amps.

In single way duct amps.

Installed in free air amps.

1.5

7

0.53

13.75

0.7

6.41

29

0.9

9.81

12.8

334

27

22

19

2.5

7

0.67

21.7

0.8

7.97

34

0.9

11.37

14.1

413

35

29

26

4

7

0.85

34.95

0.8

9.12

38

0.9

12.52

15.8

520

47

38

35

6

7

1.04

52.3

0.8

10.35

31

1.25

14.45

18

736

59

48

45

10

7

1.35

88.05

1

13.28

38

1.25

17.39

21.2

1022

78

64

62

16

7

1.75

139.5

1

-

35

1.25

-

23.1

1078

101

83

83

25

7

2.2

220

1.2

18.1

35

1.6

21.3

27.8

1623

132

107

110

35

7

2.6

305

1.2

20.2

39

1.6

25

30.6

1988

159

129

135

50

19

1.85

413

1.4

22.8

44

1.6

26

30.1

2525

188

153

163

70

19

2.2

596

1.4

25.7

39

2

29.7

34.2

3522

233

190

207

95

19

2.6

826

1.6

29.9

45

2

33.9

38.5

4548

279

228

257

120

36

2.1

1045

1.6

32.4

49

2

36.4

4.4

5409

317

260

290

150

36

2.33

1283

1.8

36.15

44

2.5

41.15

46.3

6843

355

292

322

185

36

2.6

1611

2

40.2

48

2.5

45.24

50.7

8318

401

331

378

240

60

2.33

2116

2.2

45.22

54

2.5

50.22

56.2

1048

462

382

445

300

59

2.6

2656

2.4

50.1

60

2.5

55.1

61.6

12579

517

428

510

400

60

2.88

3383

2.6

63.8

55

3.15

68.8

68

15482

580

490

590







6944X:

Table 11

Four stranded copper conductor. PVC insulated cores. Brown, Grey, Blue and Black, laid up and tape bedded, steel wire armoured. PVC Sheathed. Voltage rating 600/1000V. BS6346 - JS93. For power supply indoor, outdoor and underground.

Identification - Product identification and legend are printed on outer sheath.

Nominal area of conductor

Conductor formation

Conductor weight

Insulation

Dia over laid up cores

Armouring

Sheathing

Cable weight

Curent rating

mm sq

No. of wires

Wire size mm

g/m

Average mm

Diameter mm

mm

Wire size mm

No. of wires

Diam. Mm

Diameter (max.) mm

kg/km

In air amps

In duct amps

In ground amps

1.50

7

0.53

13.75

0.70

3.06

7.19

0.90

31

10.59

13.50

376

19

22

27

2.50

7

0.67

21.70

0.80

3.69

8.93

0.90

37

12.33

15.00

470

26

29

35

4.00

7

0.85

34.95

0.80

4.22

10.21

1.25

31

14.31

17.80

709

35

38

47

6.00

7

1.04

52.30

0.80

4.79

11.59

1.25

34

15.69

19.20

850

45

48

59

10.00

7

1.35

88.05

1.00

6.15

14.88

1.25

41

18.98

22.80

1196

62

64

78

16.00

7

1.75

139.50

1.00

6.95

16.80

1.60

34

20.00

25.90

1433

83

83

101

25.00

7

2.20

220.00

1.20

-

20.60

1.60

37

23.40

30.30

1986

110

107

132

35.00

7

2.60

305.00

1.20

-

22.60

1.60

43

25.80

33.50

2471

135

129

159

50.00

19

1.85

413.00

1.40

-

26.20

2.00

39

30.20

34.60

3367

163

153

188

70.00

19

2.20

596.00

1.40

-

29.70

2.00

45

33.70

38.40

4346

207

190

233

95.00

19

2.60

826.00

1.60

-

34.50

2.00

50

38.50

43.50

5705

251

228

276

120.00

36

2.10

1045.00

1.60

-

37.70

2.50

44

42.70

48.10

7242

290

260

317

150.00

36

2.33

1283.00

1.80

-

41.70

2.50

49

46.70

52.40

8687

332

292

355

185.00

36

2.60

1611.00

2.00

-

46.20

2.50

54

51.20

57.40

10581

378

331

401

240.00

59

2.33

2116.00

2.20

-

52.20

2.50

61

57.20

64.10

13638

445

382

462

300.00

59

2.60

2656.00

2.40

-

58.20

2.50

67

63.20

70.40

16280

510

428

517

400.00

61

2.88

3383.00

2.60

-

64.00

3.15

42

71.90

79.30

20785

590

490

580







694(3½) X

Table 12

Four core with reduced, neutral stranded copper conductor. PVC insulated laid up and tape bedded, steel wire armoured, PVC sheathed. Voltage rating 600/1000V. BS6346 - JS93. Main cores Brown, Grey and Blue, reduced neutral Black. For power supply indoor, outdoor and underground.

Identification - Product identification and legend are printed on outer sheath.

Nominal
area of conductor

Conductor formation

Conductor
weight

Insulation
thickness

Dia over
laid up
cores

Armouring

Sheathing

Cable
weight

Current rating

(pha e)

(neutral)

``(phase)
mm sq

(neutral)
mm sq

No. of
wires

Wire
size mm

No. of
wires

Wire
size mm

(phase)
kg/km

(neutral)
kg/km

(phase)
mm

(neutral)
mm

mm

Wire
size mm

No. of
wires

Diam.
mm

Diameter
(max.) kg/km

mm

in air
amps

in duct
amps

in ground
amps

25.0

16.0

7

2.20

7

1.75

220.0

139.5

1.20

1.00

19.60

1.60

38

22.80

29.3

1909

110

107

132

35.0

16.0

7

2.60

7

1.75

305.0

139.5

1.20

1.00

21.80

1.60

44

25.00

31.7

2321

135

129

159

50.0

25.0

19

1.85

7

1.75

413.0

220.0

1.40

1.20

25.20

1.60

48

28.40

32.7

3179

163

153

188

70.0

35.0

19

2.20

7

2.60

596.0

305.0

1.40

1.20

28.50

2.00

44

32.50

37.2

4055

207

190

233

95.0

50.0

19

2.60

19

1.85

826.0

413.0

1.60

1.40

32.90

2.00

49

36.90

42.9

5447

251

228

276

120.0

70.0

36

2.10

19

2.20

1045.0

596.0

1.60

1.40

36.50

2.00

44

41.50

47.8

6806

290

260

317

150.0

70.0

36

2.33

19

2.20

1283.0

596.0

1.80

1.40

40.70

2.50

48

45.70

50.8

7441

332

292

355

185.0

95.0

36

2.60

19

2.60

1611.0

826.0

2.00

1.60

44.20

2.50

55

49.20

56.0

9740

378

331

401

240.0

120.0

59

2.33

36

1.20

2116.0

1045.0

2.20

1.60

51.00

2.50

61

56.00

62.1

12134

445

380

462

300.0

150.0

59

2.60

36

2.33

2656.0

1283.0

2.40

1.80

55.80

2.50

68

60.80

68.2

14646

510

428

517

400.0

185.0

61

2.88

36

2.60

3383.0

1611.0

2.60

2.00

65.60

3.15

55

71.90

76.6

18835

590

490

580







694(7)X

Table 13

Seven core circular stranded copper conductor. PVC insulated cores. White numbered 1-7 laid up and extruded bedded, steel wire armoured, PVC sheathed. Voltage rating 600/100V. BS6346 - JS93. Auxiliary power cable.

Identification - Product identification and legend are printed on outer sheath.

Nominal area of conductor

Conductor
formation

Conductor
weight

Insulation

Dia. over
laid up cores

Armouring

Sheathing

Cable
weight

Current
resistance

mmsq

No. of wires

Wire size mm

kci/hm

avg. thkns. mm

diam. mm

mm

wire size mm

No. of wires

EEE zEE

Diameter mm

kg/km

ohm/km

1.5

7

0.53

13.75

0.7

3.06

7.95

0.9

34

15.2

14.15

470

12.1

2.5

7

0.67

21.7

0.8

3.69

10.44

1.25

32

18

16.84

729

7.41

4

7

0.85

34.95

0.8

4.22

12.66

1.25

33

20.5

19.69

940

4.61







694(12)X

Table 14

Twelve core circular stranded copper conductor. PVC insulated cores. White numbered 1-12 laid up and extruded bedded, steel wire armoured, PVC sheathed. Voltage rating 600/1000V. BS6346 - JS93. Auxiliary power cable.

Identification - Product identification and legend are printed on outer sheath.

Nominal area of conductor

Conductor
formation

Conductor
weight

insulation

Dia. over
laid up
cores

Armouri g

Sheathing

Cable
weight

Current
resistance

mm se

No. of
wires

wire
size mm

kg/km

avg. thkns.
mm

diam.
mm

mm

wire
size mm

No. of
wires

diam.
mm

Diameter
(max.) mm

kg/km

ohm/lon

1.5

7

0.53

13.75

0.7

3.06

11.2

1.25

39

15.2

19.4

784

12.1

2.5

7

0.67

21.7

0.8

3.69

15.5

1.25

42

19.45

22.4

1049

7.41

4

7

0.85

34.95

0.8

4.22

17.56

1.6

37

22.76

26.8

1560

4.61







694(19)X

Table 15

Nineteen core circular stranded copper conductor. PVC insulated cores. White numbered 1-19 laid up and extruded bedded, steel wire armoured, PVC sheathed. Voltage rating 600/1000V. BS6346 - JS93. Auxiliary power cable.

Identification - Product identification and legend are printed on outer sheath.

Nominal area of onductor

Conductor formation

Conductor weight

Insulation

Dia. over laid up cores

Armouring

Sheathing

Cable weight

Conductor resistance

mm s9

No. of wires

wire size mm

kg/km

avg. thkns. mm

diam. mm

mm

wire size mm

No. of wires

diam. mm

Diameter (max.) mm

kg/km

ohm/km

1.5

7

0.53

13.75

0.7

3.06

13.25

1.25

38

17.35

22.2

1023

12.1

2.5

7

0.67

21.7

0.8

3.69

18.45

1.6

38

23.65

26.6

1584

7.41

4

7

0.85

34.95

0.8

4.22

21.1

1.6

44

26.6

30.5

2080

4.61







694(27)X

Table 16

Twenty-seven core circular stranded copper conductor. PVC insulated cores. White numbered 1-27 laid up and extruded bedded, steel wire armoured, PVC sheathed. Voltage rating 600/1000V. BS6346-JS93. Auxiliary power cable.

Identification - Product identification and legend are printed on outer sheath.

Nominal area of conductor

Conductor formation

Conductor weight

Insulation

Dia. over laid up COCOS

Armouring

Sheathing

CO* weight

Current resist...

mm se

No. of wires

wire size mm

kg/km

avg. thkns. mm

diam mm

mm

wire size mm

No. of wires

diam. mm

Diameter (max.) mm

kg/km

ohm/km

1.5

7

0.53

13.75

0.7

3.06

16.32

1.6

35

21.52

26.7

1506

12.1

2.5

7

0.67

21.7

0.8

3.69

21.42

1.6

43

26.62

30.7

2043

7.41







694(37)X

Table 17

Thirty-seven core circular stranded copper conductor. PVC insulated SWA/PVC power cables & cores. White numbered 1-37, laid up and extruded bedded, steel wire armoured, PVC sheathed. Voltage rating 600/1000V. BS6346 - JS93. Auxiliary power cable.

Identification - Product identification and legend are printed on outer sheath.

Nominal area of conductor

Conductor formation

Conductor weight

Insulation

Dia. over laid up cores

Armouring

Sheathing

Cable weight

Current resistance

mm sq

No. of wires

wire size mm

kg/km

avg. thkns. mm

diam mm

mm

wire size mm

No. of wires

diam. mm

Diameter (max) mm

kg/km

ohm/km

1.5

7

0.53

13.75

0.7

3.06

18.55

1.6

39

23.75

29.2

1834

12.1

2.5

7

0.67

21.7

0.8

3.69

24.36

1.6

47

29.56

34

2360

7.41













CONTACT CENTER

YATSA CORPORATION

4250 Broadway I Suite 3W

NEW YORK, NY. US 10033

 

(347) 351-9094

yatsacorporation@gmail.com